    Kewtech EZYPAT-PLUS PAT Tester

    The Kewtech EZYPAT-PLUS PAT Tester is an easy-to-use, non–downloading, battery operated PAT Tester optimised for testing Class I and Class II appliances, including items which require a power supply in order to be fully tested, i.e. appliances with electronic on/off switches such as computers and TVs. Furthermore, this PAT tester can also be used to examine extension leads.

    The Kewtech EZYPAT-PLUS PAT Tester is the intermediate model in Kewtech’s range of new EZYPAT/ SMARTPAT PAT testers (for more information regarding these models please see the comparison table under the ‘Technical Specifications’). Therefore in addition to including all the tests and features found on the EZYPAT , the EZYPAT-PLUS can also conduct leakage tests at 110V and 230V.

    Like its sister product, the EZYPAT, this instrument can perform:

    • 200mA earth continuity tests (IT safe)
    • Appliance status pre-check (can be used to check whether the appliance under investigation is on or off)
    • Quick continuity check (1 second)
    • 5-second continuity check
    • 250V DC insulation tests (IT safe)
    • 500V DC insulation tests
    • Substitute leakage tests (with selectable parameters)
    • Extension lead tests

    Moreover, the individually labelled function keys facilitate the user’s ability to run automatic test sequences customised for Class I and Class II appliances and extension leads; whilst the Kewtech EZYPAT-PLUS PAT Tester’s Test Lead Null setting ensures that insulation readings are not affected by the resistance found in the its test leads.

    The accompanying EZYLEAD Extension Lead Adapter; EZYEARTH Earth Continuity Test Lead with Probe and Crocodile Clip and EZYMAIN Mains Lead all work to ensure that this PAT tester can be quickly and easily adapted to perform numerous tests in a variety of environments.

    The results of these tests are clearly indicated on the Kewtech EZYPAT-PLUS PAT Tester’s large, easy-to-read, backlit display which turns red in the event of a failed test and green in the event of a passed one.

    The Kewtech EZYPAT-PLUS PAT Tester is also ergonomically designed and lightweight making it practical as well as versatile and easy-to-use. Its battery operation also adds to its practicality, as this PAT tester can perform up to approximately 1400 tests before the batteries begin to expire.

    Therefore the Kewtech EZYPAT-PLUS PAT Tester is the ideal solution to intermediate PAT Testing requirements.

    Kewtech EZYPAT PAT Tester – Battery Operated Technical Specifications

    Protective Conductor Resistance Test
    Measuring Range0.00 – 20.00 Ω (NULL value inc)*
    Over-range Indication> 20.00 Ω
    Resolution0.01Ω
    Open-circuit Voltage5 V ±0.4 V DC
    Measuring Current200 mA DC (nominal value)
    Accuracy±3%rdg ±5dgt
    * Resistances exceeding 3 Ω cannot be cancelled by NULL function.
    Mains Voltage
    Display Range30 – 270 V
    Hi/Lo Indication< 30 V: No voltage indication
    > 270 V: 270 V
    Resolution & Accuracy1 V ±3%rdg ±5dgt
    Insulation
    Measuring Range0.00 – 20.00 MΩ
    Over-range Indication> 20.00 MΩ
    Resolution0.01 MΩ
    No-load Voltage250V : 250 V DC 20%, -0%
    500V: 500 V DC 20%, -0%
    Short-circuit Current1.5 mA DC or less
    Rated Current250V: 1 -1.2 mA with a load of 0.25 MΩ
    500V: 1 to 1.2 mA with a load of 0.5 MΩ
    Accuracy±2%rdg±3dgt
    Substitute Leakage
    Measuring Range0.10 – 12.00 mA rms
    Over-range Indication> 12.00 mA
    Resolution0.01mA
    Open-circuit Voltage/ Frequency30 V ±5 V rms / 50 Hz ±5%
    Measuring Circuit1.2 mA AC ±0.5 mA (when measuring 12.00 mA)
    Accuracy±3%rdg±5dgt
    Insulation Testy Between L-N
    Open-circuit Voltage4.5 V ±0.5 V DC
    Criteria of Judgement100 kΩ ±20 kΩ or less: LCD shows “<0.10 MΩ” and the measurement is halted.
    Run Leakage
    Mains Voltage Range100 – 253 V / 50 Hz
    Measuring RangeLoad Current: 0.10 – 13.00 A rms
    Leakage Current: 0.10 – 20.00 mA rms
    Display RangeLoad Current: 0.00 – 13.00 A
    Leakage Current: 0.00 – 20.00 mA
    Over-range IndicationLoad Current: > 13.00 A
    Leakage Current: > 20.00 mA
    ResolutionLoad Current: 0.01A
    Leakage Current: 0.01mA
    AccuracyLoad Current: ±10%rdg ±5dgt
    Leakage Current: ±3%rdg ±5dvgt
    Max. RatingLoad Current: 3 kVA max. / 15 sec. cont.
    Leakage Current: –
    Physical Specifications
    SafetyIEC/EN61010-1 CAT II 300V-instrument
    IEC/EN61010-2-030
    IEC/EN61010-031 CAT III 600V
    EMCEN61326-1, 2-2
    Possible number of
    measurements where
    battery voltage is within the
    effective range (measuring
    every 30 sec)
    Approx. 1400 times
    (CLI Rpe: 0 Ω, Rins: 1.1 MΩ)
    Boxed Weight1.82Kg
    Boxed Dimensions (L x W x D)261 x 140 x 130mm

    Kewtech EZYPAT/ SMARTPAT Comparision Table

    SpecificationEZYPATEZYPAT PLUSSMARTPAT
    200mA Continuity TestXXX
    250V Insulation TestXXX
    500V Insulation TestXXX
    Substitute Leakage TestXXX
    Polarity CheckXXX
    110V Load and Run TestXX
    230V Load and Run TestXX
    Portable RCD TestX
    Compatible with KEWPAT AppX
    Customisable Test SequencesX
    • Non-downloading PAT tester optimised for testing Class I and Class II appliances as well as extension leads
    • Battery-operated
    • Suited to testing appliances with electronic on/off switches, i.e. items that need to be powered on in order to be fully tested
    • Includes all the features found on the EZYPAT
    • 200mA earth continuity tests (IT safe)
    • Appliance status pre-check (can be used to check whether the appliance under investigation is on or off)
    • Quick continuity check (1 second)
    • 5-second continuity check
    • 250V DC insulation tests (IT safe)
    • 500V Dc insulation tests
    • Substitute leakage tests (with selectable parameters)
    • Extension lead tests
    • IT safe
    • EZYPAT-PLUS also performs leakage tests at 110V and 230V
    • Individually labelled function keys allow the user to run tailored automatic test sequences
    • Test Lead Null setting
    • EZYLEAD Extension Lead Adapter
    • EZYEARTH Earth Continuity Test Lead with Probe and Crocodile Clip
    • EZYMAIN Mains Lead
    • Large, easy-to-read, backlit display
    • Display turns green when a test is passed
    • Display turns red when a test is failed
    • Ergonomic and lightweight
    • Can perform up to 1400 tests before batteries begin to expire
    • Kewtech EZYPAT-PLUS PAT Tester –Battery Operated
    • EZYLEAD Extension Lead Adapter
    • EZYEARTH Earth Continuity Test Lead with Probe and Crocodile Clip
    • EZYMAIN Mains Lead
    • Carry Bag with Strap
    • Quick Start Guide
    • End of Line Calibration Certificate