01785 600 691enquiries@thecalcentre.co.uk

Save

17%

On RRP

Fluke i30 AC/DC Current Clamp (30A)

£454.01 Inc VAT: £544.81

    Available on back-order

    SKU FLUKE i30 Categories , Brand:

    Description

    Fluke i30 AC/DC Current Clamp (30A)

    The Fluke i30 AC/DC Current Clamp (30A) is used to measure AC and DC current and attached to other devices such as multimeters to enable current measurements to be taken.

    Featuring 19mm diameter jaws, this clamp is best suited to clamping onto smaller cables/conductors and can measure from 30mA to 30A DC and 30mA to 20A AC rms.

    This device uses hall effect technology to carry out measurements and provides accurate measurements of current without the need to break a circuit or use a full clamp meter.

    Fluke i30 Technical Specifications

    Specified current range
     30 mA to 30A dc, 30 mA to 20 A ac rms
    Usable current range
     5 mA to 30 A dc, 30 mA to 20 A ac rms
    Crest Factor
     1.4″
    Output sensitivity
     100 mV/A
    Accuracy (at 25 °C)
     ± 1 % of reading ± 2 mA
    Resolution
     ± 1 mA
    Load impedance
     > 10 k Ohms and ≤ 100pF
    Conductor position sensitivity
     ± 1 % relative to center reading
    Frequency range
     DC to 20 kHz (- 0.5 dB)
    Temperature coefficient
     ± 0.01 % of reading/°C
    Power supply
     9 V Alkaline, MN1604/PP3, 30 hours, low battery indicator
    Working voltage (see Safety Standards section)
     300 V ac rms or dc
    General Specifications
    Maximum conductor size
     19 mm diameter
    Output connection
     4 mm safety connector
    Output zero
     Manual adjust via thumbwheel
    Cable length
     1.5 meters
    Operating temperature range
     0 °C to 50 °C
    Storage temperature range (with battery removed)
     -20 °C to 85 °C
    Operating humidity
     15 % to 85 % (non-condensing)
    Weight
     250 g
    Safety standards
     BS EN 61010-1:2001
     BS EN 61010-2-032:2002
     BS EN 61010-031:2002
     300 Vrms, Category III, Pollution Degree 2
     Use of the probe on uninsulated conductors is limited to 300 V ac rms or dc and frequencies below 1 kHz.
    EMC Standards
     EN 61326: 1998 A1, A2, & A3
    • Measures both AC and DC current
    • Attaches to other types of meter
    • Hall effect technology