Description
Fluke 922 Airflow Meter Kit
The Fluke 922 Airflow Meter Kit has a handheld tester that is used to accurately measure air pressure, air velocity, air flow (volume) and temperature. It’s an ideal tester for use in the HVAC industry and can be used to measure pressure drops across filters and coils, match ventilation to occupant loads, monitor indoor vs outdoor pressure relationships and to perform duct traversals for accurate airflow readings.
Designed with versatility in mind, the 922 is made to accept the vast majority of different pitot tube types. The unit also allows measurement accuracy to be extremely high by allowing the technician to enter the exact dimensions and shape of the duct being tested.
This tester also features multiple measurement units for each available testing parameter. It can measure air pressure in pascals, H20, mm H20, mbar and PSI, air velocity in fpm and m/s, air flow (volume) in cfm, m3/hr and l/s and temperature in both Celsius and Fahrenheit. You can view the full measurement range of this tester in the technical specifications section below.
Worried about testers being easily damaged? The Fluke 922 has also been designed to resist damage and is ideal for industrial applications. It also includes a backlit screen, allowing the tester to be seen inside darkened areas such as ducts.
This version of the 922 is actual a kit that includes a number of items not usually shipped with the standard tester. It contains literally everything you’ll need to use the 922 effectively in HVAC work include a pitot tube, two rubber hoses, a carrying case and much more.
Note: The 922 is also available on its own
Fluke 922 Technical Specifications
Air Pressure | Range/Resolution/Accuracy | ± 4000 Pascals / 1 Pascal / ± 1 % 1 Pascal | | ± 16 in H2O / 0.001 in H2O / ± 1 % 0.01 in H2O | | ± 400 mm H2O / 0.1 mm H2O / ± 1 % 0.1 mm H2O | | ± 40 mbar / 0.01 mbar / ± 1 % 0.01 mbar | | ± 0.6 PSI / 0.0001 PSI / ± 1 % 0.0001 PSI |
|
Air Velocity | Range/Resolution/Accuracy | 250 to 16,000 fpm / 1 fpm / ± 2.5 % of reading at 2000 fpm (10.00 m/s) | | 1 to 80 m/s / 0.001 m/s / ± 2.5 % of reading at 2000 fpm (10.00 m/s) |
|
Air Flow (Volume) | Range/Resolution/Accuracy | 0 to 99,999 cfm / 1 cfm / Accuracy is a function of velocity and duct size | | 0 to 99,999 / 1 m3/hr / Accuracy is a function of velocity and duct size | | 0 to 99,999 l/s / 1 l/s / Accuracy is a function of velocity and duct size |
|
Temperature | Range/Resolution/Accuracy | 0 °C to 50 °C / ± 1 % 2 °C / 0.1 °C | | 32 °F to 122 °F / ± 1 % 4 °F / 0.1 °F |
|
General Specifications |
Operating Temperature | | 0 °C to 50 °C ( 32 °F to 122 °F) |
|
Storage Temperature | | -40 °C to 60 °C (-40 °F to 140 °F) |
|
Relative Humidity | | 0% to 90%, non-condensing |
|
IP Rating | |
Operating Altitude | |
Storage Altitude | |
EMI, RFI, EMC | | Meets requirements for EN61326-1 |
|
Vibration | |
Max Pressure at Each Port | |
Data storage capacity | |
Warranty | |
Power, battery life | |
Battery Life | | 280 hours without backlight, 60 hours with backlight |
|