Fluke 707Ex Intrinsically Safe Loop Calibrator

The Fluke 707Ex Intrinsically Safe Loop Calibrator is a fast response, one-handed instrument designed to allow you to safely perform mA loop checks in potentially hazardous explosive areas.

Fully certified in accordance with ATEX directive EX II 2 G Ex ia IIC T4 for use in zone 1 and 2 applications, the Fluke 717Ex includes all of the functionality you’ll need for loop calibration applications, with reliable, accurate and safe results every time it is used.

Fluke’s 707Ex calibrator includes a wide variety of diferent functions – it can be used to measure voltage from 0 to 28V with resolution of 0.001V, can be used to measure, source and simulate mA and also functions as a loop supply up to 24V DC.

This loop calibrator has many other additional extras – it can simultaneously display mA and % readouts, has a push button with 25% steps for linearity checks, can be used to perform 0-100% span checks and it is also has HART compatible resistance suitable for connection in series with the loop supply for compatibility with HART communicators.

Fluke 707Ex Technical Specifications

Function Range Resolution Accuracy
Voltage Measurement 0 to 28V 0.001V ±(0.015% rdg + 2 counts)
mA Measurement 0 to 24mA 0.001mA ±(0.015% rdg + 2 LSD)
mA Source 0 to 24mA¹ 0.001mA ±(0.015% rdg + 2 LSD)
mA Simulation 0 to 24mA² 0.001mA ±(0.015% rdg + 2 LSD)
Loop Supply 24V DC n/a 24V ±1V DC, no load
Additional Specifications
Maximum Voltage 28V
Non Operating Temperature -30 to 60°C
Operating Temperature -10 to 50°C
Relative Humidity 0 to 95% (0 to 30°C)
0 to 75% (30 to 40°C)
45% up to 50°C
Operating Altitude 3000m max
Shock and Vibration Per MIL-T-28800 for a class 2 instrument
Safety CSA C22.2 No. 1010: 1992
ATEX Certification Ex II 2 G Ex ia IIC T4 Zones 1 and 2
ZELM 02 ATEX 0120 X
FM Certification N.I. Class 1, Division 2, Groups A-D
CE Certification EN61010-1 and EN61326
Size (without holster) 152 x 70 x 47mm (H x W x D)
Size (with holster) 164 x 75 x 47mm (H x W x D)
Weight 0.28kg (no holster)
0.42kg (with holster and stand)
Battery 1 9V alkaline
Battery Life 18 hours typical, at 12mA into 500 ohms
Warranty 1 year

Temperature coefficient: -10 to 18°C, 28 to 55°C, ±0.005% of range per °C

¹Max load: 700Ω at 20mA

²Max applied voltage for simulation: 28V

  • Precise loop calibrator suitable for use in explosive hazardous environments
  • ATEX directive EX II 2 G Ex ia IIC T4 compliant for use in zone 1 and 2
  • Large-size display with simple, quick-click push rotary button for easy, one-handed operation
  • Simultaneous mA and % readout for quick, easy interpretation of readings
  • mA accuracy of 0.015% – superior compared to many other loop calibrators
  • Push button with 25% steps for fast, easy linearity checks
  • 0-100% span check for fast confirmation of zero and span
  • Selectable slow ramp, fast ramp and step ramp to provide smooth outputs for valve slewing and loop functional tests
  • Internal loop supply – use the 707Ex to power and read a transmitter at the same time without using a digital multimeters
  • Measures DC voltage to 28V
  • Innovative output adjustment dial with 0.001mA and 0.1mA resolution
  • HART compatible resistance is connected in series with the loop supply for compatibility with HART communicators
  • 1 year warranty from Fluke
  • Fluke 708Ex Loop Calibrator
  • Safety Designed Test Leads
  • Alligator Test Clips
  • Holster
  • Instruction Manual (on CD)
  • 707Ex CCD Content Control Drawing
  • CE, CSA, FM and ATEX Markings

Fluke 707ex datasheet

You may also like…