Description
Fluke 115 Field Service Technician’s Digital Multimeter
Compact true-rms meter for field service technicians. The Fluke 115 Field Service Technician’s Digital Multimeter is the solution for a wide variety of electrical and electronic testing applications. With features such as conformance to the latest safety standards, backlight, and a much larger display that’s easier to view, this meter is a must have for every toolbox.
Fluke 115 Technical Specifications
Specifications |
Maximum voltage between any terminal and earth ground | |
Surge protection | | 6 kV peak per IEC 61010-1 600 VCAT III, Pollution Degree 2 |
|
Display | Digital: | 6,000 counts, updates 4 per second |
|
Bar graph | | 33 segments, updates 32 per second |
|
Operating Temperature | |
Storage Temperature | |
Battery type | | 9 volt Alkaline, NEDA 1604A/ IEC 6LR61 |
|
Battery Life | | 400 hours typical, without backlight |
|
Accuracy Specifications |
DC millivolts | Range: | 600.0 mV | Resolution: | 0.1 mV | Accuracy: | ± ([% of reading] [counts]): 0.5% 2 |
|
DC volts | Range/Resolution: | 6.000 V / 0.001 V | Range/Resolution: | 60.00 V / 0.01 V | Range/Resolution: | 600.00 V / 0.1 V | Accuracy: | ± ([% of reading] [counts]): 0.5% 2 |
|
AC millivolts1 true-rms | Range: | 600.0 mV | Resolution: | 0.1 mV | Accuracy: | 1.0 % 3 (dc, 45 Hz to 500 Hz)2.0 % 3 (500 Hz to 1 kHz) |
|
AC volts1 true-rms | Range/Resolution: | 6.000 V / 0.001 V | Range/Resolution: | 60.00 V / 0.01 V | Range/Resolution: | 600.0 V / 0.1 V | Accuracy: | 1.0 % 3 (dc, 45 Hz to 500 Hz)2.0 % 3 (500 Hz to 1 kHz) |
|
Continuity | Range: | 600 Ω | Resolution: | 1 Ω | Accuracy: | Beeper on < 20 Ω, off > 250 Ω; detectsopens or shorts of 500 μs or longer. |
|
Ohms | Range/Resolution: | 600.0 Ω / 0.1 Ω | Range/Resolution: | 6.000 kΩ / 0.001 kΩ | Range/Resolution: | 60.00 kΩ / 0.01 kΩ | Range/Resolution: | 600.0 kΩ / 0.1 kΩ | Range/Resolution: | 6.000 MΩ / 0.001 MΩ | Accuracy: | 0.9 % 1 | Range/Resolution: | 40.00 MΩ / 0.01 MΩ | Accuracy: | 5 % 2 |
|
Diode Test | Range/Resolution: | 2.00 V / 0.001 V | Accuracy: | 0.9% 2 |
|
Capacitance | Range/Resolution: | 1000 nF / 1 nF | Range/Resolution: | 10.00 µF / 0.01 µF | Range/Resolution: | 100.0 µF / 0.1 µF | Range/Resolution: | 9999 µF / 1 µF | Range/Resolution: | 100 µF to 1000 µF | Accuracy: | 1.9% 2 | Range/Resolution: | > 1000 µF | Accuracy: | 5% 20% |
|
Lo-Z Capacitance | Range: | 1 nF to 500 µF | Accuracy: | 10% 2 typical |
|
AC amps true-rms (45 Hz to 500Hz) | Range/Resolution: | 6.000 A / 0.001 A | Range/Resolution: | 10.00 A / 0.01 A | Accuracy: | 1.5% 3 | | 20 A overload for 30-seconds max |
|
DC amps | Range/Resolution: | 6.000 A / 0.001 A | Range/Resolution: | 10.00 A / 0.01 A | Accuracy: | 1.0% 3 | | 20 A overload for 30-seconds max |
|
Hz (V or A input)2 | Range/Resolution: | 99.99 Hz / 0.01 Hz | Range/Resolution: | 999.9 Hz / 0.01 Hz | Range/Resolution: | 9.999 kHz / 0.001 kHz | Range/Resolution: | 50 kHz / 0.01 kHz | Accuracy: | 0.1% 2 |
|
Notes:
1) All ac voltage ranges except Auto-V/LoZ are specified from 1 % to 100 % of range. Auto-V/LoZ is specified from 0.0 V.
2) Temperature uncertainty (accuracy) does not include the error of the thermocouple probe.
3) Frequency is ac coupled, 5 Hz to 50 kHz for ac voltage. Frequency is dc coupled, 45 Hz to 5 kHz for ac current.
4) Temperature Range/Resolution: -40 °F to 752 °F / 0.2 °F
2) Frequency is ac coupled, 5Hz to 30 kHz for ac voltage
Mechanical & General Specifications |
Size | | 167 x 84 x 46 mm (6.57″ x 3.31″ x 1.82″) |
|
Weight | |
Warranty | |