01785 600 691enquiries@thecalcentre.co.uk

Save

57%

On RRP

Kewtech EZYPAT PAT Tester

£315.00 Inc VAT: £378.00

    Add a 12 month Calibration Certificate

    SKU Kewtech EZYPAT Categories , Brand:

    Description

    Kewtech EZYPAT PAT Tester

    The Kewtech EZYPAT PAT Tester is battery operated and capable of performing up to approximately 1400 tests before the batteries begin to expire. This PAT tester has been optimised to perform manual dead tests on Class I and Class II appliances as well as extension leads.

    The Kewtech EZYPAT is the simplest model in Kewtech’s EZYPAT/ SMARTPAT range; for more information on the models within this range, please see the comparison table in the ‘Technical Specifications’.

    The Kewtech EZYPAT can perform an array of tests, including:

    • Appliance status pre-check (determines whether the appliance under investigation is on or off)
    • Quick check continuity (1 second)
    • 5-second continuity check
    • Insulation tests (user selectable 250V DC or 500V DC)
    • Substitute leakage test (user selectable limits)
    • Extension lead test
    • 200mA earth test

    The Kewtech EZYPAT’s inclusion of a low current earth continuity test and 250V insulation test ensures that it is IT safe, whilst its Test Lead Null setting ensures that the user is able to attain accurate insulation measurements which are unaffected by the resistance of the test leads.

    In addition to this, it features clearly labelled function buttons which allow the user to run automatic test sequences for Class I and Class II appliances, as well as extension cables. The results of all these tests are indicated via the EZYPAT’s large, easy-to-read, backlit display, which turns green for PASS and red for FAIL.

    This product’s convenience is further improved by its lightweight and ergonomic design; extension lead adapter and earth continuity test lead with probe and crocodile clip, these features and accessories ensure that the EZYPAT is suitable for use in a variety of environments and can be easily adapted to perform multiple tests.

    The battery operated Kewtech EZYPAT PAT Tester is versatile, convenient and efficient, the ideal portable appliance tester for those who wish to perform manual dead tests on items that do NOT require a power supply to switch on, i.e. appliances WITHOUT electronic on/off switches.

    (PLEASE NOTE that the EZYPAT PLUS is suited to testing items (such as computers and TVs) with electronic on/off switches and which do require a power supply to start up.)

    Kewtech EZYPAT PAT Tester – Battery Operated Technical Specifications

    Protective Conductor Resistance Test
    Measuring Range0.00 – 20.00 Ω (NULL value inc)*
    Over-range Indication> 20.00 Ω
    Resolution0.01Ω
    Open-circuit Voltage5 V ±0.4 V DC
    Measuring Current200 mA DC (nominal value)
    Accuracy±3%rdg ±5dgt
    * Resistances exceeding 3 Ω cannot be cancelled by NULL function.
    Insulation
    Measuring Range0.00 – 20.00 MΩ
    Over-range Indication> 20.00 MΩ
    Resolution0.01 MΩ
    No-load Voltage250V : 250 V DC 20%, -0%
    500V: 500 V DC 20%, -0%
    Short-circuit Current1.5 mA DC or less
    Rated Current250V: 1 -1.2 mA with a load of 0.25 MΩ
    500V: 1 to 1.2 mA with a load of 0.5 MΩ
    Accuracy±2%rdg±3dgt
    Substitute Leakage
    Measuring Range0.10 – 12.00 mA rms
    Over-range Indication> 12.00 mA
    Resolution0.01mA
    Open-circuit Voltage/ Frequency30 V ±5 V rms / 50 Hz ±5%
    Measuring Circuit1.2 mA AC ±0.5 mA (when measuring 12.00 mA)
    Accuracy±3%rdg±5dgt
    Insulation Testy Between L-N
    Open-circuit Voltage4.5 V ±0.5 V DC
    Criteria of Judgement100 kΩ ±20 kΩ or less: LCD shows “<0.10 MΩ” and the measurement is halted.
    Physical Specifications
    SafetyIEC/EN61010-1 CAT II 300V-instrument
    IEC/EN61010-2-030
    IEC/EN61010-031 CAT III 600V
    EMCEN61326-1, 2-2
    Possible number of
    measurements where
    battery voltage is within the
    effective range (measuring
    every 30 sec)
    Approx. 1400 times
    (CLI Rpe: 0 Ω, Rins: 1.1 MΩ)
    Boxed Weight1.61Kg
    Boxed Dimensions (L x W x D)261 x 140 x 130mm

     

    Kewtech EZYPAT/ SMARTPAT Comparision Table

    SpecificationEZYPATEZYPAT PLUSSMARTPAT
    200mA Continuity TestXXX
    250V Insulation TestXXX
    500V Insulation TestXXX
    Substitute Leakage TestXXX
    Polarity CheckXXX
    110V Load and Run TestXX
    230V Load and Run TestXX
    Portable RCD TestX
    Compatible with KEWPAT AppX
    Customisable Test SequencesX
    • Battery operated PAT Tester ideal for performing manual dead tests on appliances that do not require a power supply to switch on (WITHOUT electronic on/off switches)
    • Can perform up to approximately 1400 tests before the batteries expire
    • Appliance status pre-check (determines whether the appliance under investigation is on or off)
    • Quick check continuity (1 second)
    • 5-second continuity check
    • Insulation tests (using either 250 or 500V DC)
    • Substitute leakage test
    • Extension lead test
    • 200mA earth test
    • Low current earth continuity and 250V insulation test make the EZYPAT IT safe
    • Test Lead Null setting
    • Automatic test sequences for Class I and Class II appliances and extension leads
    • Large, easy-to-read, backlit display
    • Red and green PASS/ FAIL screens
    • Lightweight, ergonomic design
    • Extension lead adapter
    • Earth continuity test lead, probe and crocodile clip
    • Selectable insulation test voltages: 250V DC and 500V DC
    • Selectable substitute leakage test limits
    • Kewtech EZYPAT PAT Tester – Battery Operated
    • EZYLEAD Extension Lead Adapter
    • EZYEARTH Earth Continuity Test Lead with Probe and Crocodile Clip
    • Carry Bag with Strap
    • Quick Start Guide